How do I switch my Cylia thermodynamic water heater to antibacterial mode ?
- During the Legionella prevention cycle, the water temperature is raised to 60°C by the heat pump.
- If the hot water setting is already set to 60°C, there will be no Legionella prevention cycle since it is permanent.
- If a cycle is interrupted by a prohibition period (EDF signal or other external contact), it will be restarted at the next authorization period.
- Once the temperature reaches 60°C, the cycle stops automatically.
How do I switch my thermodynamic water heater to antibacterial mode?
- Press and hold the "Turbo" button for 3 seconds to enter the menu.
- Press the "Turbo" button twice to access the "Antibacterial Mode".
- Confirm the function with the "Temperature" button.
- Press and hold the "Turbo" button for 3 seconds to exit the menu.