Connect and declare an outdoor sensor in AUTO mode
- Connect the outdoor sensor (ref. 710157) to terminals 3 and 4 of the boiler.
Use parameter 07 to declare an outdoor sensor
- In the parameter settings menu, set parameter 07 to value 01: presence of an outdoor sensor.
Activatable option (recommended) "AUTO mode": automatic temperature control (by water law)
- From the standard display, switch the boiler to automatic mode by pressing the auto/manual button.
- Manual mode = a point is lit at the bottom right of the top display.
- Auto mode = the point is off.
Activatable option: automatic Summer / Winter switch
- In the parameter settings menu, set parameter 10 to value 01: automatic switch.
These questions might also interest you
How to adjust the speed of the circulator?Performing a partial or total shedding of the boiler ?Can the power of Gialix be reduced ?What needs to be done to install the domestic hot water production ?Use off-peak / peak hours signal.How to control the boiler with an external controller ?How to connect and declare a room thermostat ?How to access the installer settings ?Information and heating setpoint calculated by boilerHow to program time slots ?What thermostat can I connect ?