How to control the boiler with an external controller ?
Connect the output of the controller to terminals 7 and 8 of the boiler.
- The output of the controller should be a dry contact, operated according to the logic:
- Closed contact = required comfort level
- Open contact = required setpoint reduction
Use parameter 23 to choose the setpoint reduction level
- In the parameter settings menu, set parameter 23 to the value:
- 01: Setpoint reduction to ECO setpoint when the external controller contact is open
- 02: Setpoint reduction to FROST protection when the external controller contact is open
These questions might also interest you
How to adjust the speed of the circulator?
Performing a partial or total shedding of the boiler ?
Can the power of Gialix be reduced ?
What needs to be done to install the domestic hot water production ?
Use off-peak / peak hours signal.
How to connect and declare a room thermostat ?
Connect and declare an outdoor sensor in AUTO mode
How to access the installer settings ?
Information and heating setpoint calculated by boiler
How to program time slots ?
What thermostat can I connect ?